MV ABC Aerial Bundled Cable (IEC 60502)
Application
Medium Voltage aerial bundled cables are mainly used for secondary overhead lines on poles,clamped to tunnel walls or as feeders for homes.


Standard
IEC 60502-2---- Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV).
Voltage
6.35/11Kv, 19/33kV
Construction
Phase Conductor | Class 2 Circular compacted stranded Aluminum |
Conductor Screen | Extruded semi-conductive layer |
Insulation | XLPE (Cross-linked polyethylene) |
Insulation Screen | Extruded semi-conductive layer |
Metallic Screen | Copper tape or wire mesh |
Separator | Semi-conductive swellable tape |
Outer Sheath | HDPE (High Density polyethylene) |
Support Conductor | wires made of Galvanized steel wires |
Construction
Self-Supporting System:
It is composed of four core hard drawn and twisted aluminum conductors with the same cross-sectional area, and the insulating layer is XLPE containing carbon, which can prevent ultraviolet light.

Color
Insulated core: Red, Yellow & Blue core marking tape
Outed sheath: black
Characteristics
Operating Temperature | 90°C XLPE |
Temperature Range | -20°C PE sheath |
Short Circuit Temperature( 5 seconds maximum duration ) | 250°C XLPE |
Bending Radius | 15 x OD |
Data Sheet
IEC 60502 6.35/11 kV ABC for Overhead Distribution Lines | |||||||
Number of Cores x Nominal Cross Section | Phase Conductor | Messenger Suspension Unit | Continuous current rating at 300C ambient temp | ||||
Stranding | Nominal Sectional Area | Maximum Conductor Resistance | Stranding | Nominal Sectional Area | Breaking Load | ||
No.×mm^2 | No.×mm | mm^2 | Ω/Km | No.×mm | mm^2 | KN | A |
3X50 + 1X25 | 19/1.78 | 50 | 0.641 | 7/3.0 | 50 | 60 | 116 |
3X70 + 1X50 | 19/.14 | 70 | 0.443 | 7/3.15 | 50 | 62 | 210 |
3X95+ 1X50 | 19/2.52 | 95 | 0.32 | 7/3.0 | 50 | 60 | 173 |
3X185+1X120 | 37/2.52 | 185 | 0.164 | 7/4.67 | 120 | 150 | 259 |
3X150 +1X50 | 37/2.25 | 150 | 0.206 | 7/3.15 | 50 | 62 | 365 |
3X240 +1X50 | 61/2.25 | 240 | 0.125 | 7/3.15 | 50 | 62 | 500 |
IEC 60502 19/33 kV ABC for Overhead Distribution Lines | |||||||
Number of Cores x Nominal Cross Section | Phase Conductor | Messenger Suspension Unit | Continuous current rating at 300C ambient temp | ||||
Stranding | Nominal Sectional Area | Maximum Conductor Resistance | Stranding | Nominal Sectional Area | Breaking Load | ||
No.×mm^2 | No.×mm | mm^2 | Ω/Km | No.×mm | mm^2 | KN | A |
3X50 + 1X50 | 19/1.78 | 50 | 0.641 | 7/3.0 | 50 | 60 | 165 |
3X150+ 1X50 | 37/2.25 | 150 | 0.206 | 7/3.0 | 50 | 60 | 315 |
3X185+1X70 | 37/2.52 | 185 | 0.164 | 7/3.57 | 70 | 91 | 355 |
3X70 +1X50 | 19/2.14 | 7 | 0.443 | 7/3.15 | 50 | 62 | 250 |
3X150 +1X50 | 37/2.25 | 150 | 0.206 | 7/3.15 | 50 | 62 | 370 |