IEC BS 12-20kV-XLPE Insulated PVC sheathed MV Middle Voltage Power Cable

Suitable for energy networks such as power stations,distribution system etc. It usually used for installation in ducts, underground and outdoors.


Due to its robustness and high electrical stability, medium voltage cables are used in harsh environments.

    Description

    There is big difference in construction, standards and the materials used-specifying the correct MV cable for a project is a matter of balancing the performance requirements, installation demands, and environmental challenges, and then ensuring cable, industry, and regulatory compliance. With the International Electrotechnical Commission (IEC) defining Medium Voltage(MV) cables as having a voltage rating of above 1kV up to 100kV, which is  a broad voltage range to consider. Our more common idea is 3.3kV to 35kV, before it becomes high voltage. We can support cables for all voltages.

    Application

    Suitable for energy networks such as power stations,distribution system etc. It usually used for installation in ducts, underground and outdoors. 

    Due to its robustness and high electrical stability, medium voltage cables are used in harsh environments.

    Note: Red outer sheath can be prone to fading when exposed to UV rays.

    Standards

    Flame propagation to BS EN60332BS6622IEC 60502

    Cable Construction

    Conductor: stranded plain annealed circular compacted copper or aluminium conductor

    Insulation: cross link polyethylene (XLPE)

    Metallic Screen: individual or overall copper tape screen

    Separator: copper tape with 10% overlap

    Bedding: polyvinyl chloride (PVC) 

    Armoured: Steel Wire Armour (SWA), Steel Tape Armour (STA), Aluminium Wire Armour (AWA), Aluminium Tape Armour (ATA)

    Sheath: PVC/PE outer sheath

    Sheath colour: Red or Black

    Electrical data

    Conductor max operating temperature: 90°C

    Screen max operating temperature: 80°C

    Conductor max temperature during S.C: 250°C

    Laying conditions at trefoil formation

    Soil thermal resistivity: 120˚C. Cm/Watt

    Burial depth: 0.5m

    Ground temperature: 15°C

    Air temperature: 25°C

    Frequency: 50Hz

    Data Sheet

    Single-core 12/20 kV

    Nominal area conductor Conductor diameter Insulation thickness Nominal overall diameter Maximum overall diameter

    Approx. cable weight kg/km

    Minimum bending radius
    mm2 mm mm mm mm

    Cu

    Al

    mm
    1x 25 6.0 5.5 26.0 27.0

    892

    737

    380
    1x 35 7.0 5.5 27.1 28.1

    1021

    804

    390
    1x 50 8.2 5.5 28.5 29.5

    1216

    902

    410
    1x 70 9.9 5.5 30.2 31.2

    1464

    1024

    440
    1x 95 11.5 5.5 32.0 33.0

    1769

    1171

    460
    1x120 12.9 5.5 33.4 34.4

    2052

    1297

    480
    1x150 14.2 5.5 34.9 35.9

    2391

    1447

    500
    1x185 16.2 5.5 37.1 38.1

    2805

    1640

    530
    1x240 18.2 5.5 39.1 40.1

    3381

    1870

    560
    1x300 21.2 5.5 42.3 43.3

    4065

    2176

    600
    1x400 23.4 5.5 44.7 45.7

    5077

    2553

    640
    1x500 27.3 5.5 48.8 49.8

    6166

    3017

    700
    1x630 30.5 5.5 52.4 53.4

    7526

    3559

    750

    Three-cores 12/20 kV

    Nominal area conductor Conductor diameter Insulation thickness Nominal overall diameter Maximum overall diameter

    Approximate cable weight kg/km

    Minimum bending radius
    mm2 mm mm mm mm

    Cu

    Al

    mm
    3x 25 6.0 5.5 52.4 53.4

    3611

    3146

    750
    3x 35 7.0 5.5 54.5 55.5

    4083

    3432

    770
    3x 50 8.2 5.5 57.4 58.4

    4771

    3826

    810
    3x 70 9.9 5.5 61.2 62.2

    5714

    4392

    870
    3x 95 11.5 5.5 65.0 66.0

    6810

    5015

    920
    3x120 12.9 5.5 68.2 69.2

    7847

    5580

    970
    3x150 14.2 5.5 71.2 72.2

    9000

    6166

    1010
    3x185 16.2 5.5 75.6 76.6

    10481

    6986

    1070
    3x240 18.2 5.5 80.5 82.0

    12700

    8200

    1140

    Armoured three-cores-12/20 kV

    Nominal area conductor Conductor diameter Insulation thickness Nominal overall diameter Maximum overall diameter

    Approximate cable weight kg/km

    Minimum bending radius
    mm2 mm mm mm mm

    Cu

    Al

    mm
    3x 25 6.0 5.5 57.5 58.5

    5045

    4580

    820
    3x 35 7.0 5.5 59.8 60.8

    5630

    4979

    850
    3x 50 8.2 5.5 62.7 63.7

    6381

    5436

    890
    3x 70 9.9 5.5 66.5 67.5

    7450

    6128

    940
    3x 95 11.5 5.5 70.1 71.1

    8614

    6820

    990
    3x120 12.9 5.5 73.5 74.5

    9780

    7513

    1040
    3x150 14.2 5.5 76.3 77.3

    10962

    8128

    1080
    3x185 16.2 5.5 80.9 81.9

    12611

    9116

    1140
    3x240 18.2 5.5 85.5 86.5

    14792

    10258

    1210